Goto

Collaborating Authors

 motion artifact


Inter-Beat Interval Estimation with Tiramisu Model: A Novel Approach with Reduced Error

arXiv.org Artificial Intelligence

Inter-beat interval (IBI) measurement enables estimation of heart-rate variability (HRV) which, in turns, can provide early indication of potential cardiovascular diseases. However, extracting IBIs from noisy signals is challenging since the morphology of the signal is distorted in the presence of the noise. Electrocardiogram (ECG) of a person in heavy motion is highly corrupted with noise, known as motion-artifact, and IBI extracted from it is inaccurate. As a part of remote health monitoring and wearable system development, denoising ECG signals and estimating IBIs correctly from them have become an emerging topic among signal-processing researchers. Apart from conventional methods, deep-learning techniques have been successfully used in signal denoising recently, and diagnosis process has become easier, leading to accuracy levels that were previously unachievable. We propose a deep-learning approach leveraging tiramisu autoencoder model to suppress motion-artifact noise and make the R-peaks of the ECG signal prominent even in the presence of high-intensity motion. After denoising, IBIs are estimated more accurately expediting diagnosis tasks. Results illustrate that our method enables IBI estimation from noisy ECG signals with SNR up to -30dB with average root mean square error (RMSE) of 13 milliseconds for estimated IBIs. At this noise level, our error percentage remains below 8% and outperforms other state of the art techniques.


Physically-Constrained Harmonic Separation for Robust Heart and Respiratory Rate Estimation from Wrist Photoplethysmography

arXiv.org Artificial Intelligence

Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with physiological dynamics. Existing signal-processing methods degrade under strong motion, while unconstrained deep learning approaches often lack physiological interpretability and identifiable structure. We propose a Physically-Constrained Harmonic Separation (PCHS) framework that formulates HR and RR estimation from wrist PPG as an analysis-by-synthesis problem, where accelerometer measurements condition artifact separation rather than directly regressing vital signs. A physics-guided harmonic generator decomposes the observed signal into quasi-periodic physiological components and a motion-related residual, enabling HR recovery from the fundamental frequency and RR prediction from respiratory-driven modulations of the harmonic parameters. Robust reconstruction objectives, separation constraints, and uncertainty-aware weighting stabilize the decomposition under motion. Experiments on the motion-intensive PPG-DaLiA dataset demonstrate that PCHS outperforms state-of-the-art methods while yielding interpretable signal decompositions that effectively disentangle physiological activity from motion artifacts.


WearBCI Dataset: Understanding and Benchmarking Real-World Wearable Brain-Computer Interfaces Signals

arXiv.org Artificial Intelligence

Brain-computer interfaces (BCIs) have opened new platforms for human-computer interaction, medical diagnostics, and neurorehabilitation. Wearable BCI systems, which typically employ non-invasive electrodes for portable monitoring, hold great promise for real-world applications, but also face significant challenges of signal quality degradation caused by motion artifacts and environmental interferences. Most existing wearable BCI datasets are collected under stationary or controlled lab settings, limiting their utility for evaluating performance under body movement. To bridge this gap, we introduce WearBCI, the first dataset that comprehensively evaluates wearable BCI signals under different motion dynamics with synchronized multimodal recordings (EEG, IMU, and egocentric video), and systematic benchmark evaluations for studying impacts of motion artifact. Specifically, we collect data from 36 participants across different motion dynamics, including body movements, walking, and navigation. This dataset includes synchronized electroencephalography (EEG), inertial measurement unit (IMU) data, and egocentric video recordings. We analyze the collected wearable EEG signals to understand the impact of motion artifacts across different conditions, and benchmark representative EEG signal enhancement techniques on our dataset. Furthermore, we explore two new case studies: cross-modal EEG signal enhancement and multi-dimension human behavior understanding. These findings offer valuable insights into real-world wearable BCI deployment and new applications.


Shift-Invariant Feature Attribution in the Application of Wireless Electrocardiograms

arXiv.org Artificial Intelligence

Assigning relevance scores to the input features of a machine learning model enables to measure the contributions of the features in achieving a correct outcome. It is regarded as one of the approaches towards developing explainable models. For biomedical assignments, this is very useful for medical experts to comprehend machine-based decisions. In the analysis of electro cardiogram (ECG) signals, in particular, understanding which of the electrocardiogram samples or features contributed most for a given decision amounts to understanding the underlying cardiac phases or conditions the machine tries to explain. For the computation of relevance scores, determining the proper baseline is important. Moreover, the scores should have a distribution which is at once intuitive to interpret and easy to associate with the underline cardiac reality. The purpose of this work is to achieve these goals. Specifically, we propose a shift-invariant baseline which has a physical significance in the analysis as well as interpretation of electrocardiogram measurements. Moreover, we aggregate significance scores in such a way that they can be mapped to cardiac phases. We demonstrate our approach by inferring physical exertion from cardiac exertion using a residual network. We show that the ECG samples which achieved the highest relevance scores (and, therefore, which contributed most to the accurate recognition of the physical exertion) are those associated with the P and T waves. Index Terms Attribution, baseline, cardiovascular diseases, electrocardiogram, activity recognition, machine learning


Causal Inference for Preprocessed Outcomes with an Application to Functional Connectivity

arXiv.org Machine Learning

In biomedical research, repeated measurements within each subject are often processed to remove artifacts and unwanted sources of variation. The resulting data are used to construct derived outcomes that act as proxies for scientific outcomes that are not directly observable. Although intra-subject processing is widely used, its impact on inter-subject statistical inference has not been systematically studied, and a principled framework for causal analysis in this setting is lacking. In this article, we propose a semiparametric framework for causal inference with derived outcomes obtained after intra-subject processing. This framework applies to settings with a modular structure, where intra-subject analyses are conducted independently across subjects and are followed by inter-subject analyses based on parameters from the intra-subject stage. We develop multiply robust estimators of causal parameters under rate conditions on both intra-subject and inter-subject models, which allows the use of flexible machine learning. We specialize the framework to a mediation setting and focus on the natural direct effect. For high dimensional inference, we employ a step-down procedure that controls the exceedance rate of the false discovery proportion. Simulation studies demonstrate the superior performance of the proposed approach. We apply our method to estimate the impact of stimulant medication on brain connectivity in children with autism spectrum disorder.


SmoothSync: Dual-Stream Diffusion Transformers for Jitter-Robust Beat-Synchronized Gesture Generation from Quantized Audio

arXiv.org Artificial Intelligence

Co-speech gesture generation is a critical area of research aimed at synthesizing speech-synchronized human-like gestures. Existing methods often suffer from issues such as rhythmic inconsistency, motion jitter, foot sliding and limited multi-sampling diversity. In this paper, we present SmoothSync, a novel framework that leverages quantized audio tokens in a novel dual-stream Diffusion Transformer (DiT) architecture to synthesis holistic gestures and enhance sampling variation. Specifically, we (1) fuse audio-motion features via complementary transformer streams to achieve superior synchronization, (2) introduce a jitter-suppression loss to improve temporal smoothness, (3) implement probabilistic audio quantization to generate distinct gesture sequences from identical inputs. To reliably evaluate beat synchronization under jitter, we introduce Smooth-BC, a robust variant of the beat consistency metric less sensitive to motion noise. Comprehensive experiments on the BEAT2 and SHOW datasets demonstrate SmoothSync's superiority, outperforming state-of-the-art methods by -30.6% FGD, 10.3% Smooth-BC, and 8.4% Diversity on BEAT2, while reducing jitter and foot sliding by -62.9% and -17.1% respectively. The code will be released to facilitate future research.


ProDM: Synthetic Reality-driven Property-aware Progressive Diffusion Model for Coronary Calcium Motion Correction in Non-gated Chest CT

arXiv.org Artificial Intelligence

Coronary artery calcium (CAC) scoring from chest CT is a well-established tool to stratify and refine clinical cardiovascular disease risk estimation. CAC quantification relies on the accurate delineation of calcified lesions, but is oftentimes affected by artifacts introduced by cardiac and respiratory motion. ECG-gated cardiac CTs substantially reduce motion artifacts, but their use in population screening and routine imaging remains limited due to gating requirements and lack of insurance coverage. Although identification of incidental CAC from non-gated chest CT is increasingly considered for it offers an accessible and widely available alternative, this modality is limited by more severe motion artifacts. We present ProDM (Property-aware Progressive Correction Diffusion Model), a generative diffusion framework that restores motion-free calcified lesions from non-gated CTs. ProDM introduces three key components: (1) a CAC motion simulation data engine that synthesizes realistic non-gated acquisitions with diverse motion trajectories directly from cardiac-gated CTs, enabling supervised training without paired data; (2) a property-aware learning strategy incorporating calcium-specific priors through a differentiable calcium consistency loss to preserve lesion integrity; and (3) a progressive correction scheme that reduces artifacts gradually across diffusion steps to enhance stability and calcium fidelity. Experiments on real patient datasets show that ProDM significantly improves CAC scoring accuracy, spatial lesion fidelity, and risk stratification performance compared with several baselines. A reader study on real non-gated scans further confirms that ProDM suppresses motion artifacts and improves clinical usability. These findings highlight the potential of progressive, property-aware frameworks for reliable CAC quantification from routine chest CT imaging.


Robust Photoplethysmography Signal Denoising via Mamba Networks

arXiv.org Artificial Intelligence

Photoplethysmography (PPG) is widely used in wearable health monitoring, but its reliability is often degraded by noise and motion artifacts, limiting downstream applications such as heart rate (HR) estimation. This paper presents a deep learning framework for PPG denoising with an emphasis on preserving physiological information. In this framework, we propose DPNet, a Mamba-based denoising backbone designed for effective temporal modeling. To further enhance denoising performance, the framework also incorporates a scale-invariant signal-to-distortion ratio (SI-SDR) loss to promote waveform fidelity and an auxiliary HR predictor (HRP) that provides physiological consistency through HR-based supervision. Experiments on the BIDMC dataset show that our method achieves strong robustness against both synthetic noise and real-world motion artifacts, outperforming conventional filtering and existing neural models. Our method can effectively restore PPG signals while maintaining HR accuracy, highlighting the complementary roles of SI-SDR loss and HR-guided supervision. These results demonstrate the potential of our approach for practical deployment in wearable healthcare systems.


Multimodal signal fusion for stress detection using deep neural networks: a novel approach for converting 1D signals to unified 2D images

arXiv.org Artificial Intelligence

This study introduces a novel method that transforms multimodal physiological signals -- photoplethysmography (PPG), galvanic skin response (GSR), and acceleration (ACC) -- into 2D image matrices to enhance stress detection using convolutional neural networks (CNNs). Unlike traditional approaches that process these signals separately or rely on fixed encodings, our technique fuses them into structured image representations that enable CNNs to capture temporal and cross - signal dependencies more effectively. This image - based transformation not only improves interpretability but also serves as a rob ust form of data augmentation. To further enhance generalization and model robustness, we systematically reorganize the fused signals into multiple formats, combining them in a multi - stage training pipeline. This approach significantly boost s classification performance, with test accuracy improving from 92.57% (using individual signal orderings) to 95.86% when using the combined strategy. While demonstrated here in the context of stress detection, the proposed method is broadly applicable to any domain invo lving multimodal physiological signals, paving the way for more accurate, personalized, and real time health monitoring through wearable technologies.


StableMotion: Training Motion Cleanup Models with Unpaired Corrupted Data

arXiv.org Artificial Intelligence

Motion capture (mocap) data often exhibits visually jarring artifacts due to inaccurate sensors and post-processing. Cleaning this corrupted data can require substantial manual effort from human experts, which can be a costly and time-consuming process. Previous data-driven motion cleanup methods offer the promise of automating this cleanup process, but often require in-domain paired corrupted-to-clean training data. Constructing such paired datasets requires access to high-quality, relatively artifact-free motion clips, which often necessitates laborious manual cleanup. In this work, we present StableMotion, a simple yet effective method for training motion cleanup models directly from unpaired corrupted datasets that need cleanup. The core component of our method is the introduction of motion quality indicators, which can be easily annotated - through manual labeling or heuristic algorithms - and enable training of quality-aware motion generation models on raw motion data with mixed quality. At test time, the model can be prompted to generate high-quality motions using the quality indicators. Our method can be implemented through a simple diffusion-based framework, leading to a unified motion generate-discriminate model, which can be used to both identify and fix corrupted frames. We demonstrate that our proposed method is effective for training motion cleanup models on raw mocap data in production scenarios by applying StableMotion to SoccerMocap, a 245-hour soccer mocap dataset containing real-world motion artifacts. The trained model effectively corrects a wide range of motion artifacts, reducing motion pops and frozen frames by 68% and 81%, respectively. Results and code are available at https://yxmu.foo/stablemotion-page